The Formation of Abscesses in the Peritoneal Cavity and the Left Internal Obturator Muscle as the Complications of the Transobturator Tape Procedure
- Abstract
- The synthetic, tension-free midurethral sling procedure using transobturator tape (TOT) was introduced in 2001. Since then, it has become a mainstream modality in patients with stress urinary incontinence. But, it has been reported to produce many complications such as mesh erosion, hematoma formation, and abscess. We experienced a case of abscess formation in the peritoneal cavity and left internal obturator muscle seven days after the TOT sling procedure, for which we performed a complete removal of mesh and a percutaneous drainage of the peritoneal abscess using 10.2-F drain-fix at the department of interventional radiology. To our knowledge, our case is one of the serious complications of the TOT procedure. Here, we report our case with a review of literatures.
- All Author(s)
- S. M. Shim
; M. G. Jo
; Y. S. Kim
- Issued Date
- 2014
- Type
- Article
- Keyword
- Abscess; Stress urinary incontinence; Suburethral slings
- Publisher
- Soonchunhyang Medical Research Institute
- ISSN
- 2233-4289
; 2233-4297
- Citation Title
- Soonchunhyang Medical Science
- Citation Volume
- 20
- Citation Number
- 1
- Citation Start Page
- 45
- Citation End Page
- 47
- Language(ISO)
- eng
- DOI
- 10.15746/sms.14.011
- URI
- http://schca-ir.schmc.ac.kr/handle/2022.oak/2189
- 공개 및 라이선스
-
- 파일 목록
-